PC 347
Certificate Details
- Certificate Number: PC 347
- Document ID: ZWAY250226
- Expiration: Monday, 24 February 2031
Main Certification Holder Details
- Company Name: ZWAYA ALFKR ALSHAMLT LLC
- Company Address: As Saqsuq, Barka, South Al Batinah Governate, Oman
Certification Details
- Scheme: Q-Plus Product Conformity Scheme for Fire Door
- Certificate Status: Active
- Certification Type: Single Site Certification
- Certificate maintenance: Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
- Surveillance Audit Status: No Pending
Scope of Certification
|
Test Report Ref. |
Product Description |
Tested Results/Properties |
Test Standard |
|
|
Integrity |
Insulation |
|||
|
ML_FRR-2303/6331 C2-2 (2303221059) |
Zwaya_Latched, Single-Acting, Single Leaf Wooden Doorset with or without Vision Panel_ 54mm thick ALTUS FD-60 Core_Non-Loadbearing Assembly_SP1 |
60 minutes |
30 minutes (Up to 44 minutes) |
BS 476 Part 22:1987 Amd. 2014 |
· No alterations shall be made to any product specifications or parameters mentioned in the test report such as design, components, performance criteria without
prior approval from CCS. Any violation of this requirement will invalidate existing test reports and certification approvals.
· Test reports shall not be combined with primary FoA reports. It is crucial to follow the test reports precisely to ensure accurate results and reliable product performance.
|
Test Report / Assessment Report Ref. |
Product Description |
Tested Results/Properties |
Test Standard |
|
|
Integrity |
Insulation |
|||
|
ML_FRR-2403/ 480 C1-2 (2401241131) (CCS/E-25132, Rev. 0) |
Zwaya_Latched, Single-Acting, Double or Single Leaf Wooden Doorset with or without Vision Panel_54mm thick ALTUS FD-60 Core_Non-Loadbearing Assembly |
60 minutes (Up to 62 minutes) |
60 minutes (Up to 62 minutes) |
BS EN 1634-1: 2014 + A1: 2018 |
|
ML_FRR-2306/1427 (2401201130) (CCS/E-25132, Rev. 0) |
Zwaya_Latched, Single-Acting, Double or Single Leaf Wooden Doorset with or without Vision Panel_64mm thick Fireblock Altus FD-90 Core_Non-Loadbearing Assembly |
90 minutes (Up to 95 minutes) |
90 minutes (Up to 95 minutes) |
BS EN 1634-1: 2014 + A1: 2018 |
· No alterations shall be made to any product specifications or parameters mentioned in the test assessment such as design, components, performance criteria. Any violation of this requirement will invalidate existing test assessment and certification approvals.