PC 336 - Certification, Testing, Fire Test, Inspection, Training and Technical Services | CCS Conformity Certification Services

PC 336

  • Certificate Details

  • Certificate Number: PC 336
  • Document ID: MONO100925
  • Expiration: Monday, 09 September 2030
  • Main Certification Holder Details

  • Company Name: MONOLITH FIRE RESISTANT WOOD INDUSTRY
  • Company Address: 11 Breej 5 St., Mussafah M-42, Abu Dhabi, United Arab Emirates
  • Certification Details

  • Scheme: Q-Plus Product Conformity Scheme for Fire Door
  • Certificate Status: Active
  • Certification Type: Single Site Certification
  • Certificate maintenance: Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
  • Surveillance Audit Status: No Pending

Scope of Certification

Test Report Ref. Product Description Tested Results/Properties Test Standard
Integrity Insulation Others
ML_FRR-2412/2236 (2412101177) Monolith_Latched, Single Acting, Single Leaf Wooden Doorset with or without Vision Panel_54mm thick USI 60 ProShield Core_Non-Loadbearing Assembly_SP1 90 minutes (up to 91 minutes) 60 minutes (up to 61 minutes) Radiation = 5 kW/m2 (at 55 minutes) BS EN 1634-1: 2014+A1:2018
ML_FRR-2412/2236 (2412101177) Monolith_Latched, Single Acting, Single Leaf Wooden Doorset with or without Vision Panel_64mm thick USI 90 ProShield Core_Non-Loadbearing Assembly_SP2 90 minutes (up to 91 minutes) 90 minutes (up to 91 minutes) Radiation = 10 kW/m2 (at 86 minutes) BS EN 1634-1: 2014+A1:2018
ML_FRR-2501/2773 (2501101180) Monolith_Latched, Single Acting, Double Leaf Wooden Doorset with or without Vision Panel_54mm thick USI 60 ProShield Core_Non-Loadbearing Assembly 60 minutes (up to 61 minutes) 60 minutes (up to 61 minutes) Radiation = 10 kW/m2 (at 59 minutes) BS EN 1634-1: 2014+A1:2018
ML_FRR-2507/15001 (2507281194) Monolith_Latched, Single Acting, Double Leaf Wooden Doorset with or without Vision Panel_50mm thick Xyloban Core_Non-Loadbearing Assembly 90 minutes (up to 92 minutes) 90 minutes (up to 92 minutes) - BS 476 Part 22:1987 (Amd. 2014)
·          No alterations shall be made to any product specifications or parameters mentioned in the test report such as design, components, performance criteria without prior approval from CCS. Any violation of this requirement will invalidate existing test reports and certification approvals.
·          Test reports shall not be combined with primary FoA reports. It is crucial to follow the test reports precisely to ensure accurate results and reliable product performance.
back to top

Need help?