PC 329
Certificate Details
- Certificate Number: PC 329
- Document ID: ALUF040325
- Expiration: Sunday, 03 March 2030
Main Certification Holder Details
- Company Name: ALUFORM GLASS AND ALUMINIUM FACTORY L.L.C.
- Company Address: P.O. Box 231249, Al Qusais Industrial Area 4, Dubai, United Arab Emirates
- Participating Site(s): NONE
- Nominated Agent(s): NONE
Certification Details
- Scheme: Q-Plus Product Conformity Scheme for Fire Door and Fire Building Enclosure
- Certificate Status: Active
- Certification Type: Single Site Certification
- Certificate maintenance:
Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
Note: No Q-Plus Labels is issued yet
- Surveillance Audit Status: No Pending
Scope of Certification
| Test Report Ref. | Product Description | Tested Results/Properties | Test Standard | ||
| Integrity | Insulation | Radiation | |||
| ML_FRR 2110/5036 C1-4 (211027922) | Aluform_Latched, Single Acting, Fully Glazed, Aluminium Framed Double Leaf Doorset in Associated Supporting Construction_ Vetrotech Contraflam Lite 30 Mono & IGU Glazing in Aluprof MB-78 Framing_Non-Loadbearing Assembly | 120 minutes (Up to 122 minutes) | I2 = 35 minutes I1 = 35 minutes | 120 minutes (Up to 121 minutes) | BS EN 1634-1:2014+ A1:2018 |
| TBWIC SL151-1A (Rev. 01) | Aluform_Latched, Single Acting, Fully Glazed, Insulated Aluminium Double Leaf with Side and Over Panels Doorset_27mm thick Vetrotech Contraflam 60-3 Glazing in Aluprof MB-78EI Framing_Non-Loadbearing Assembly | 60 minutes | 60 minutes | 60 minutes | BS EN 1634-1:2014+ A1:2018 |
| ML/FRR-1910/327 C1-2 (190916702) | Aluform_Fully Glazed, Fixed Partition_13mm thick Pyroguard T-EW60/ 13-1 Glazing in Aluprof MB-78EI Framing System_ Non-Loadbearing Assembly | 60 minutes | - | 31 minutes @ 15 kW/m2 | BS EN 1364-1:2015 |
| ML_FRR-2104/396 C1-4 (210404873) | Aluform_Insulated, Fully Glazed, Aluminium Framed Fixed Partition EW 120_13mm thick Vetrotech Contraflam Lite 30 SGU and 29mm thick Vetrotech Contraflam Lite 30 IGU Glazing in Aluprof MB-78EI System_Non-Loadbearing Assembly | 120 minutes (Up to 132 minutes) | 56 minutes | 120 minutes (Up to 132 minutes) | BS EN 1364-1:2015 |
· Test reports shall not be combined with primary FoA reports. It is crucial to follow the test reports precisely to ensure accurate results and reliable product performance.