PC 282 - Certification, Testing, Fire Test, Inspection, Training and Technical Services | CCS Conformity Certification Services

PC 282

  • Certificate Details

  • Certificate Number: PC 282
  • Document ID: MARM280922
  • Expiration: Friday, 27 September 2030
  • Main Certification Holder Details

  • Company Name: MARMI ENGINEERING COMPANY W.L.L
  • Company Address: P.O Box.37592, Office No.12, 1st Floor, Gate No.12, Arkan Building, Commercial Ave, Doha, Qatar
  • Certification Details

  • Scheme: Q-Plus Product Conformity Scheme for Fire Door
  • Certificate Status: Active
  • Certification Type: Single Site Certification
  • Certificate maintenance: Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
  • Surveillance Audit Status: No Pending

Scope of Certification

Assessment Report Product Description Tested Results/Properties Test Standard
Integrity Insulation
WF_FEA/F97174 Marmi Engineering Company_Wooden Doorset with Timber Frame_Halspan Prima 30 Core_Non-Loadbearing Assembly 30 minutes - BS 476 Part 22:1987 Amd. 2014
WF_FEA/F96103 Marmi Engineering Company_ Wooden Doorset_Halspan Prima 60 Core_Non-Loadbearing Assembly 60 minutes - BS 476 Part 22:1987 Amd. 2014
WF_Chilt/A01204 Part 1 Marmi Engineering Company_Wooden Doorset with Timber Frame_Halspan Optima 30 Core_Non-Load Bearing Assembly 30 minutes - BS 476 Part 22:1987 Amd. 2014
WF_Chilt/A01205 Part 1 Marmi Engineering Company_Wooden Doorset_54mm thick Halspan Optima 60 Core_Non-Load Bearing Assembly 60 minutes - BS 476 Part 22:1987 Amd. 2014
WF_Chilt/A05151 Marmi Engineering Company_Wooden Doorset_64mm thick Halspan 90 Core_Non-Load Bearing Assembly 90 minutes - BS 476 Part 22:1987 Amd. 2014
WF_BMT/CNA/F15082 Marmi Engineering Company_Wooden Doorset_Halspan 120 Composite Core _Non-Loadbearing Assembly 120 minutes - BS 476 Part 22:1987 Amd. 2014
IFC_PAR/10346/01 Rev. F Marmi Engineering Company_Timber/Steel Framed Wooden Leaf Doorset _44mm thick Solid and 46 mm & 47mm thick Composite_FireBAN FD30 Core 30 minutes - BS 476 Part 22:1987
IFC_PAR/10346/02 Rev. G Marmi Engineering Company_Timber/Steel Framed Wooden Leaf Doorset_54mm & 64mm thick Solid and 56mm thick Composite_FireBAN FD60 Core 60 minutes - BS 476 Part 22:1987
IFC_PAR/11018/01 Rev. E Marmi Engineering Company_Timber/Steel Framed Wooden Leaf Doorset_64mm thick Solid & Composite and 54mm thick Plus_FireBAN FD90 Core 90 minutes - BS 476 Part 22:1987
IFC_PAR/13335/01 Rev. C Marmi Engineering Company_Timber/Steel Framed Wooden Leaf Doorset_64mm thick Composite and 64mm thick Plus_FireBAN FD120 Core 120 minutes - BS 476 Part 22:1987
·          No alterations shall be made to any product specifications or parameters mentioned in the test assessment such as design, components, performance criteria. Any violation of this requirement will invalidate existing test assessment and certification approvals.
back to top

Need help?

 Leave us your name and phone number and we'll call you back shortly.