PC 222
Certificate Details
- Certificate Number: PC 222
- Document ID: ABUD100520
- Expiration: Tuesday, 09 May 2028
Main Certification Holder Details
- Company Name: ABU DHABI PRECAST
- Company Address: P.O. Box 38605, ICAD 1, Abu Dhabi, United Arab Emirates
- Participating Site(s): NONE
- Nominated Agent(s): NONE
Certification Details
- Scheme: Q-Plus Product Conformity Scheme for Fire Building Enclosure
- Certificate Status: Active
- Certification Type: Single Site Certification
- Certificate maintenance: Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
- Surveillance Audit Status: No Pending
Scope of Certification
| Assessment/ Test Report | Product Description | Tested Results/ Properties | Test Standard |
| ML/FRQ-2003/886 (ML/FRR-2003/1822 & ML/FRR-2003/1821-1) | Abu Dhabi Precast_12 mm thick Non-Combustible Glass Fiber Reinforced Concrete (GRC) Panel – External Cladding Assembly, Non-loadbearing | Reaction to Fire Classification: A2-S1-d0 | EN 13501-1: 2018 (ISO 1716:2018 BS EN ISO 13823:2010 + A1:2014) |
| ML/FRR-2003/5555 (FRQ-2003/886) | Self-Ignition Temperature = > 650°C Mode of Combustion = Flaming | ASTM D1929-16 | |
| ML/FRR-2003/1823 (FRQ-2003/886) | Mass Loss = 2.65 %~2.88 % Sustained Flaming = None Temperature Rise = 4.1°C~8.5°C | BS EN ISO 1182:2010 | |
| ML/FRR-2003/6561 (FRQ-2003/886) | Ignition = None | BS EN ISO 11925- 2: 20`10 | |
| TBWIC/VA039-1 | Passed | BS 8414-2: 2020 | |
| ML/FRR-2009/1784 (ML/FR-2009/3838A & ML/FR-2009/3840A) | Abu Dhabi Precast_Glass Fiber Reinforced Plastic Composite Panel (GRP) | Reaction to Fire Classification: B-S1-d0 | EN 13501-1:2018 (BS EN ISO 11925-2: 2010 BS EN ISO 13823: 2010+A1:2014) |
| ML/FRQ-2009/1784 (FRR-2009/3839A) | Self-Ignition Temperature = 455°C | ASTM D1929-16 |