PC 222 - Certification, Testing, Fire Test, Inspection, Training and Technical Services | CCS Conformity Certification Services

PC 222

  • Certificate Details

  • Certificate Number: PC 222
  • Document ID: ABUD100520
  • Expiration: Tuesday, 09 May 2028
  • Main Certification Holder Details

  • Company Name: ABU DHABI PRECAST
  • Company Address: P.O. Box 38605, ICAD 1, Abu Dhabi, United Arab Emirates
  • Participating Site(s): NONE
  • Nominated Agent(s): NONE
  • Certification Details

  • Scheme: Q-Plus Product Conformity Scheme for Fire Building Enclosure 
  • Certificate Status: Active
  • Certification Type: Single Site Certification
  • Certificate maintenance: Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
  • Surveillance Audit Status: No Pending

Scope of Certification

Assessment/ Test Report Product Description Tested Results/ Properties Test Standard
ML/FRQ-2003/886 (ML/FRR-2003/1822 & ML/FRR-2003/1821-1) Abu Dhabi Precast_12 mm thick Non-Combustible Glass Fiber Reinforced Concrete (GRC) Panel External Cladding Assembly, Non-loadbearing Reaction to Fire Classification: A2-S1-d0 EN 13501-1:  2018 (ISO 1716:2018 BS EN ISO 13823:2010 + A1:2014)
ML/FRR-2003/5555 (FRQ-2003/886) Self-Ignition Temperature = > 650°C Mode of Combustion = Flaming ASTM D1929-16
ML/FRR-2003/1823 (FRQ-2003/886) Mass Loss = 2.65 %~2.88 % Sustained Flaming = None Temperature Rise = 4.1°C~8.5°C BS EN ISO 1182:2010
ML/FRR-2003/6561 (FRQ-2003/886) Ignition = None BS EN ISO 11925- 2: 20`10
TBWIC/VA039-1 Passed BS 8414-2: 2020
ML/FRR-2009/1784 (ML/FR-2009/3838A & ML/FR-2009/3840A) Abu Dhabi Precast_Glass Fiber Reinforced Plastic Composite Panel (GRP) Reaction to Fire Classification: B-S1-d0 EN 13501-1:2018 (BS EN ISO 11925-2: 2010 BS EN ISO 13823: 2010+A1:2014)
ML/FRQ-2009/1784 (FRR-2009/3839A) Self-Ignition Temperature = 455°C ASTM D1929-16
back to top

Need help?

 Leave us your name and phone number and we'll call you back shortly.