Test Report Ref. Product Description Tested Results/ Properties Test Standard
Integrity Insulation
ML_520606 SN 1/1 (161123384) UNIMIX_4" Solid Concrete Blocks – Non-Loadbearing Wall 240 minutes 89 minutes BS 476: Part 22:1987 Amd. 2014
ML_CR-1803/4644 SN 1/1 (180321587) UNIMIX_4" Hollow Concrete Blocks – Non-Loadbearing Wall 240 minutes 240 minutes BS 476: Part 22:1987 Amd. 2014
ML_523427 SN 1/1 (161214397) UNIMIX_6" Solid Concrete Blocks – Non-Loadbearing Wall 240 minutes 190 minutes BS 476: Part 22:1987 Amd. 2014
TBWIC_MA44-02, Rev.01 UNIMIX_6" Hollow Concrete Blocks - Non-Loadbearing Wall 240 minutes 112 minutes BS 476: Part 22: 1987
TBWIC_NL 74-1, Rev.01 UNIMIX_8" Solid Concrete Blocks – Non-Loadbearing Wall 240 minutes 240 minutes BS 476: Part 22: 1987
TBWIC_MA44-01, Rev.01 UNIMIX_8" Hollow Concrete Blocks – Non-Loadbearing Wall 240 minutes 169 minutes BS 476: Part 22: 1987
ML_FRQ-1812/1566 SN 1/1 (181206593) UNIMIX_8” Thermal Concrete Hollow Blocks – Non-Loadbearing Wall 240 minutes 240 minutes BS 476: Part 22:1987 Amd. 2014
TBWIC_NL 74-2, Rev.01 UNIMIX_10" Thermal Concrete Hollow Blocks - Non-Loadbearing Wall 240 minutes 240 minutes BS 476: Part 22: 1987