Print this page

PC 333

  • Certificate Details

  • Certificate Number: PC 333
  • Document ID: UNIB110625
  • Expiration: Monday, 10 June 2030
  • Main Certification Holder Details

  • Company Name: UNIBAL FIRE DOORS FACTORY LLC
  • Company Address: ICAD 1, 50 D14, Mussafah, Abu Dhabi, United Arab Emirates
  • Certification Details

  • Scheme: Q-Plus Product Conformity Scheme for Fire Door
  • Certificate Status: Active
  • Certification Type: Single Site Certification
  • Certificate maintenance: Validity of the Certificate is subject to Yearly / 6 month Surveillance Audit
  • Surveillance Audit Status: No Pending

Scope of Certification

Test Report Ref. Product Description Tested Results/Properties Test Standard
Integrity Insulation
ESL_0088-25-TR-01 Unibal_Latched, Single Acting, Single Leaf Wooden Doorset without Vision Panel_Non-Load Bearing Assembly 60 minutes
(up to 62 minutes)
60 minutes
(up to 62 minutes)
BS 476 Part 22:1987 Amd.2014
ESL_0378-25-TR-01 Unibal_Latched, Single Acting, Single Leaf Wooden Doorset without Vision Panel_Non-Load Bearing Assembly_Door 1 & Door 2 Door 1: 60 minutes
(up to 79 minutes) Door 2: 90 minutes
(up to 103 minutes)
Door 1: 60 minutes
(up to 79 minutes) Door 2: 90 minutes
(up to 103 minutes)
EN 1634-1: 2014+A1:2018
·          No alterations shall be made to any product specifications or parameters mentioned in the test report such as design, components, performance criteria without prior approval from CCS. Any violation of this requirement will invalidate existing test reports and certification approvals.
·          Test reports shall not be combined with primary FoA reports. It is crucial to follow the test reports precisely to ensure accurate results and reliable product performance.